Axial flow fan

  • JDMY-6# axial flow fan
JDMY-6# axial flow fan

JDMY-6# axial flow fan

  • Product description: JDMY-6# axial flow fan is widely used in general factories, warehouses, offices, residential ventilation or enhance the use of heating radiator. If the shell is unloaded, the utility model can be used
  • INQUIRY
JDMY-6 axial flow fan
Product introduction
This product is the latest design by the Shanghai Jiao Tong University, developed to surpass the world's advanced level of a new generation of products, and through technical appraisal in 1986, this product identification test aerodynamic performance index according to the national standard of GB1236-76, the noise characteristics in accordance with the provisions of the national standard GB2888-82. Identification and testing of the product performance indicators have reached or exceeded the original design indicators (with the conclusion of the organization identification unit). The test identified by Shanghai Institute of mechanical engineering, Shanghai Chemical Engineering Design Institute, Shanghai City Construction College Hospital seven, seven, four Research Institute of Shanghai Jiaotong University, Department of power engineering, Tongji University, Institute of acoustics, Shanghai Municipal Environmental Protection Bureau, Shanghai General Machinery Research Institute, Shanghai City Bureau of labor protection unit of Professor, associate professor, senior engineer, engineer in. Shanghai special steel pipe factory, construction and installation company, a steel plant and other units attended the trial and will provide the user identification report.
Two, product features
The product will be identified as follows:
1, the fan flow part of advanced design, reasonable structure, wide range of working conditions, light weight, wide application, energy saving and other advantages.
2, under the design conditions of the fan, the fan efficiency of 88.8%, the noise level of 80.3dB (A), than the A sound level of 24.6dB (A), the weight of 110 kg. Compared with the similar products known as West Germany, Italy, Denmark, Sweden, Japan and other countries have reached and exceeded some of their performance indicators. To this end, it is concluded that the aerodynamic and noise performance of the fan is equivalent to the advanced level of similar products in the early 80s.
3, ZFMY-6 type fan air volume, energy saving, low noise, pressure head, medium range, material saving, suitable for smelting, steel rolling, furnaces, slipway and other high temperature post and ventilation pipe for cooling. During the trial by the user. The significance of labor protection and environmental protection. The product has been produced by the factory, put into production, advanced equipment, reasonable technology, strong technical force, the products have passed the performance test and quality inspection. Our business objective is: to ensure the quality of the implementation of three packs, abide by the contract, delivery in a timely manner, welcome the user to negotiate a letter.
Three, the use of Maintenance Notes
1, before installation and use should check whether the fan packaging, transport improper deformation damage. If the defects need to be repaired before installation.
2, to check the installation of the fan when the connection is loose, the gap between the blade and the fan should be uniform, not rub.
3, fan installation, the weight of the ventilation pipe shall not be added to the cabinet, the installation of the wind pipe should be additional support. If the air inlet is not connected to the pipeline should be installed when the collector (Bell) to improve the flow of gas.
4, post fan when in use, the fan should be placed smoothly, as fan use, flat base should be a natural fit with the foundation, should add pad pad, do not beat the flange or connected to prevent deformation.
5, after the installation of the fan, the impeller must be first to check whether there is too tight or rub phenomenon. Impeller should be flexible rotation, before the trial operation
6, according to the requirements of the correct connection power.
7, pay attention to check the direction of rotation of the impeller should be consistent with the direction of the barrel arrow, not reverse operation.
8, the ventilator is used for a long time and then re-use, but also to conduct a comprehensive inspection and commissioning, and then put into normal operation.
9, the ventilator in normal use should be regularly checked monthly. Always pay attention to the fan in the operation of abnormal sound, vibration and excessive current phenomenon, found that the problem needs to be repaired in a timely manner, in order to extend the service life of the fan.2, the main performance parameters:
Impeller diameter: Dt=0.6 M
Volume: Q = 18000 m 3/ hours
Air pressure: Pt = 294 Pascal
Fan efficiency: ETA = 0.85
Noise: SPL = 81dB (A)
Fan: W < 2.2 kW power consumption
Speed: N = 1440 rev / min
Range: 20 m (wind speed) 2.8 m / S

 

Scan the qr codeClose
the qr code
主站蜘蛛池模板: 久久久免费看片 | 日韩欧美国产精品一区二区三区 | 成人狠狠色综合 | 7799精品视频免费观看 | 国产第一区二区 | julia中文字幕久久一区二区 | 国产模特av私拍大尺度 | 亚洲加勒比久久88色综合明星 | 欧美在线视频网 | 欧美亚洲另类色图 | 午夜影院久久 | 我要操操操 | 天堂国产永久综合人亚洲欧美 | 黄色网址视频免费 | 欧美性生活久久久 | 国产a级网站| 中文字幕av在线播放 | 欧美精品国产第一区二区 | 日本黄色动漫网站 | 中国精品久久 | 另类春色校园亚洲 | 天天天天天天干 | 秋霞一级毛片 | 黄色网址视频大全 | 成人H动漫精品一区二区无码 | 午夜精品亚洲日日做天天做 | 国产精品亚洲а∨天堂免 | 免费色婷婷 | 欧美xxxxxxxxxxx | 69视频一区 | 西欧FREE性满足HD老熟妇 | 免费a级片网站 | 国产尤物视频在线 | 97国产成人 | 国产精品毛片va一区二区 | 在线观看美女网站 | h肉动漫无遮无修在线播放18 | 色老汉av一区二区三区 | 日韩黄色片网站 | A级毛片在线视频免费观看 久久久国产一区二区三区 日本三级吃奶头添泬播放 一日本道久久久精品国产 欧美多人视频 | 激情久久网 |